The Telford Tempest Stainless Indirect Cylinders are supplied with an internal coil suitable to be fed heat by a gas or oil boiler. All models come complete with a 3kw immersion heater as backup and 22mm compression fittings. The Tempest models are supplied with a remote expansion vessel with a factory fitted wall mounting bracket.
Key Features Lifetime guarantee 2 years guarantee on components 90-500 litre domestic range High density insulation ERP Compliant Full unvented kit supplied Including remote expansion vessel & Incoloy immersion as standard (for commercial applications we recommend upgrading to Titanium) WRAS approved Tried and tested Treated to protect against corrosion Longest working life
Product Data Model:
TSM090 Capacity: 90 L Height: 750 Diameter: 510 See Image 2 A (mm): 170 B (mm): 200 C (mm): 400 D (mm): 495 E (mm): - F (mm):550 Reheat from Cold (mins): 26 Reheat from 70% Draw Off (mins) 18 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 1.37
Model: TSM125 Capacity: 125 Height: 935 Diameter: 510 See Image 2 A (mm): 170 B (mm): 200 C (mm): 400 D (mm): 495 E (mm): - F (mm): 750 Reheat from Cold (mins): 36 Reheat from 70% Draw Off (mins) 25 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 1.48
Model: TSM150 Capacity: 150 Height: 1060 Diameter: 510 See Image 2 A (mm): 170 B (mm): 200 C (mm): 400 D (mm): 495 E (mm): - F (mm):880 Reheat from Cold (mins): 37 Reheat from 70% Draw Off (mins) 6 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 1.72
Model: TSM170 Capacity: 170 Height: 1200 Diameter: 510 See Image 2 A (mm): 170 B (mm): 200 C (mm):450 D (mm): 600 E (mm): - F (mm): 1030 Reheat from Cold (mins): 36 Reheat from 70% Draw Off (mins) 25 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 1.92
Model: TSM200 Capacity: 200 Height: 1120 Diameter: 580 See Image 2 A (mm): 195 B (mm): 225 C (mm): 475 D (mm): 625 E (mm): 815 F (mm): 930 Reheat from Cold (mins): 33 Reheat from 70% Draw Off (mins) 24 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 2.04
Model: TSM250 Capacity: 250 Height: 1330 Diameter: 580 See Image 2 A (mm): 195 B (mm): 225 C (mm): 555 D (mm): 825 E (mm): 975 F (mm): 1140 Reheat from Cold (mins): 35 Reheat from 70% Draw Off (mins) 25 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 2.16
Model: TS300 Capacity: 300 Height: 1650 Diameter: 580 See Image 2 A (mm): 195 B (mm): 225 C (mm):555 D (mm): 845 E (mm): 11255 F (mm): 1435 Reheat from Cold (mins): 40 Reheat from 70% Draw Off (mins) 29 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 2.32
Model: TS400 Capacity: 400 Height: 1590 Diameter: 710 See Image 2 A (mm): 240 B (mm): 270 C (mm):640 D (mm): 1240 E (mm): 1240 F (mm): 1340 Reheat from Cold (mins): 45 Reheat from 70% Draw Off (mins) 35 ERP Band: C Immersion Rating (kW): 3 Standing Heat Loss (kWh/24h): 2.58
Please Note If you are purchasing on behalf of an installer or in preparation for your project it is important to get your installer to confirm the size of the cylinder required. Incorrectly ordered cylinders are subject to restocking fees and can be expensive to return. The returns policy for these items is strict, we can not accept returns past the dates set out in the returns policy.